FDAnews
www.fdanews.com/articles/183829-compounder-missed-marks-for-sterile-drug-processing

Compounder Missed Marks for Sterile Drug Processing

October 6, 2017

An Alabama compounding pharmacy fell short of several standards for sterile drug processing, the FDA said in a Form 483 inspection report.

Included among the findings at the pharmacy, Triad Rx, in Daphne, were:

  • Pads or wipes used to clean an isolation area were not sterile;
  • Equipment that was difficult to clean or visibly dirty was located in designated sterile areas, specifically a lyophilizer and a dehumidifier;
  • Workers touched equipment or surfaces with gloved hands outside the sterile workspaces and then processed sterile products inside those workspaces without changing or sanitizing their gloves;
  • Workers processing sterile products with hands, wrists, legs, hair or mouths exposed; and
  • A pump used in sterile processing was not properly disinfected.

View today's stories